Effectiveness and safety of different wire types for preoperative localization of pulmonary nodules: A systematic review and meta-analysis
PneumologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Wire localization systems are widely used for perioperative lung nodule localization. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of five wire types (barb-thorn, double-thorn, four-hook, spiral, and Q-type) for preoperative localization.
PubMed, Embase, Web of Science, and Cochrane databases were searched to December 2024 to retrieve data and assess risk of bias. Meta-analysis used a random effects model to obtain pooled estimates and prediction intervals (PI) for success rates, complication rates, and pain scores. Heterogeneity was explored in stratified analyses.
O que encontraram
80 studies involving 9,996 procedures across 9,049 patients were included. The pooled technical success rate for localization was 98% (95% CI: 0.98-0.99; PI: 96%-100%), while VATS success reached 100% (95% CI: 1.00-1.00; PI: 99%-100%). Major and minor complications were 0% (95% CI: 0.00-0.00; PI: 0%-1%) and 43% (95% CI: 0.36-0.50; PI: 0%-100%) (75 studies). However, Q-type wire demonstrated lower success rates and a higher risk of major complications compared to other wire types. Studies with low/some concerns showed lower minor complication rates (21%; 95% CI: 0.08-0.34) compared to moderate (44%; 95% CI: 0.35-0.52) and high-quality studies (46%; 95% CI: 0.31-0.61). Pain scores (7 studies) averaged 3.41 (95% CI: 2.60-4.22; PI: 0.32-6.50) on a 0-10 scale.
Por que isso importa
Different wire types demonstrated high localization and VATS success rates with comparable safety profiles. However, Q-type wire demonstrated lower success rates and higher complication risks, though based on limited data. Further studies are required to confirm its efficacy and safety.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Effectiveness and safety of different wire types for preoperative localization of pulmonary nodules: A systematic review and meta-analysis
Xiaowen Zhang, Zhenhui Nie, Marcel van Tuinen, C van de Wauwer, Thom R G Stams, Mathias Prokop, Geertruida H de Bock, Monique Dorrius
Descritores MeSH
- Solitary Pulmonary Nodule
- Lung Neoplasms
- Preoperative Care
- Thoracic Surgery, Video-Assisted
- Multiple Pulmonary Nodules
- Humans
Veja também
Estudos relacionados
- CT-Guided Anchored Needle Versus Hook-Wire Localization for Pulmonary Nodules: A Meta-Analysis
- Preoperative localization for pulmonary nodules: a meta-analysis of coil and liquid materials
- Use of methylene blue and a spring microcoil in the preoperative localization of small pulmonary nodules under CT guidance: a meta-analysis
- Comparison of mixed reality and computed tomography-guided preoperative hook-wire localization for pulmonary nodules in video-assisted thoracoscopic surgery: a noninferiority randomized clinical trial