ScienceMed®
Imagem de arquivo, ilustrativa: Astrócitos (em vermelho) no cérebro, em microscopia de fluorescência

Efeitos das modalidades de saída de interface cérebro-computador na recuperação motora após acidente vascular cerebral: revisão sistemática e meta-análise de rede

Ortopedia
Imagem de arquivo, ilustrativa — não é do estudo. Astrócitos (em vermelho) no cérebro, em microscopia de fluorescência. NIH · domínio público · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaFrontiers in neuroscience27 out 20260 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The relative effects of different brain-computer interface output modalities for post-stroke motor rehabilitation remain unclear.

To synthesize randomized evidence on brain-computer interface-assisted motor rehabilitation after stroke, with emphasis on functional electrical stimulation-triggered and robot-assisted output modalities and the certainty of evidence.

Sixteen randomized controlled trials published from January 2020 to October 2025 were identified from PubMed, Web of Science, Embase, IEEE Xplore, the Cochrane Library, and MEDLINE. Interventions included brain-computer interface-triggered functional electrical stimulation, brain-computer interface-controlled robotic rehabilitation, and conventional rehabilitation. The primary outcome was motor recovery measured by the Fugl-Meyer Assessment. A frequentist random-effects network meta-analysis was performed, and certainty of evidence was assessed using CINeMA.

O que encontraram

No trial directly compared the two active brain-computer interface modalities, resulting in a star-shaped network. Compared with conventional rehabilitation, brain-computer interface-triggered functional electrical stimulation improved motor recovery (standardized mean difference 0.57, 95% confidence interval 0.12 to 1.01), whereas brain-computer interface-controlled robotic rehabilitation showed an uncertain effect (0.17, -0.25 to 0.60). The indirect comparison numerically favored brain-computer interface-triggered functional electrical stimulation over brain-computer interface-controlled robotic rehabilitation, but the confidence interval crossed the null (0.39, -0.22 to 1.01). Certainty was limited by indirectness, imprecision, and heterogeneity.

Por que isso importa

Brain-computer interface-triggered functional electrical stimulation showed a clearer signal of benefit vs. conventional rehabilitation than brain-computer interface-controlled robotic. However, the comparison between the two active modalities relies entirely on indirect evidence from a star-shaped network, has very low confidence, and does not establish comparative superiority. P-score rankings are exploratory pending direct head-to-head trials.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.