Drug-coated balloons versus drug-eluting stents in patients with acute myocardial infarction undergoing percutaneous coronary intervention: an updated meta-analysis with trial sequential analysis
CardiologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Drug-coated balloons (DCBs) are an established strategy for coronary artery disease. However, the new generation drug-eluting stent (DES) is recommended for patients with Acute myocardial infarction (AMI) for coronary artery revascularization. Our aim is to provide a comprehensive appraisal of the efficacy of DCBs in patients with AMI undergoing PCI.
We searched the WOS, PubMed, Scopus, and Cochrane CENTRAL till March 2023, for studies that compared DCBs versus DES in patients with AMI undergoing PCI. We used a random-effects model to compare major adverse cardiac events (MACE), cardiac death, all-cause death, myocardial infarction, target lesion revascularization (TLR), stent thrombosis, Late lumen Loss (LLL), and minimum lumen diameter (MLD) between the two groups.
CRD42023412757.
O que encontraram
Thirteen studies comprising 2644 patients were included. The pooled OR showed non-inferiority of DCB over DES in terms of MACE (OR = 0.89, 95% CI [0.57 to 1.40], p = 0.63). When we defined MACE as a composite of cardiac death, MI, and TLR; the pooled OR favored DCB over DES (OR = 0.50, 95% CI [0.28 to 0.9], p = 0.02). Moreover, DCB was not inferior to DES in terms of all-cause mortality (OR = 0.88, 95% CI: 0.43 to 1.8, p = 0.73), cardiac mortality, (OR = 0.59, 95% CI: 0.22 to 1.56, p = 0.29), MI (OR = 0.88, 95% CI: 0.34 to 2.29, p = 0.79), stent thrombosis (OR = 1.21, 95% CI: 0.35 to 4.23, p = 0.76), TLR (OR = 0.9, 95% CI: 0.43 to 1.93, p = 0.8), LLL (MD = -0.6, 95% CI: -0.3 to 0.19, p = 0.64), or MLD (MD = -0.4, 95% CI: -0.33 to 0.25, p = 0.76).
Por que isso importa
Our meta-analysis indicated that DCB intervention was not inferior to DES in the PCI setting in patients with AMI, and can be recommended as a feasible strategy in AMI.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Drug-coated balloons versus drug-eluting stents in patients with acute myocardial infarction undergoing percutaneous coronary intervention: an updated meta-analysis with trial sequential analysis
Ahmed Abdelaziz, Abdelrahman Hafez, Karim Atta, Hanaa Elsayed, Mohamed Abdelaziz, Ahmed Elaraby, Hallas Kadhim, Ahmed Mechi, Mahmoud Ezzat, Ahmed Fadel et al.
Descritores MeSH
- Percutaneous Coronary Intervention
- Thrombosis
- Drug-Eluting Stents
- Coronary Artery Disease
- Myocardial Infarction
- Death
- Humans
- Treatment Outcome
Veja também
Estudos relacionados
- Intravascular imaging guided versus coronary angiography guided percutaneous coronary intervention: systematic review and meta-analysis
- Impact of acute and persistent stent malapposition after percutaneous coronary intervention on adverse cardiovascular outcomes
- Efficacy of intravascular imaging-guided drug-eluting stent implantation: a systematic review and meta-analysis of randomized clinical trials
- Comparison of biodegradable and newer generation durable polymer drug-eluting stents with short-term dual antiplatelet therapy: a systematic review and Bayesian network meta-analysis of randomized trials comprising of 43,875 patients