Diagnostic performance of qualitative and quantitative methods of meibomian gland dropout evaluation in dry eye disease: An investigator-masked, randomised crossover study
OftalmologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
To evaluate the discriminative abilities and optimal cut-off values of qualitative meiboscale grading and percentage meibomian gland dropout measurements from each of two instruments (Keratograph 5M and LipiView II) in detecting dry eye disease, as defined by the TFOS DEWS II criteria.
A total of 227 community residents (143 females, 84 males; mean ± SD age, 36 ± 15 years) were recruited in a prospective, investigator-masked, randomised, crossover study. Dry eye symptomology, tear film parameters, and ocular surface characteristics were evaluated in a single clinical session. Qualitative meiboscale grading and quantitative percentage gland dropout assessment using Image J software were evaluated by independent masked assessors, in a randomised order.
O que encontraram
Overall, 92 (41 %) participants fulfilled the TFOS DEWS II criteria for dry eye disease. The diagnostic performances for percentage meibomian gland dropout measurements (C-statistic range, 0.629 to 0.647) were significantly greater than qualitative meiboscale grading (C-statistic range, 0.547 to 0.560) for both instruments. The Youden-optimal diagnostic cut-off percentage gland dropout was > 20 % and optimal threshold meiboscale grade was > 1 for both superior and inferior eyelid measurements from the two instruments. Inter-instrument weighted Cohen's kappa coefficients for meiboscale grading were 0.734 and 0.682, respectively, and Bland-Altman biases (95 % limits of agreement) for percentage gland dropout were -1.8 % (-28.1 % to 24.4 %) and -1.5 % (-29.3 % to 26.2 %), respectively.
Por que isso importa
Despite exhibiting comparable discriminative abilities, meibography parameters obtained from the Keratograph and LipiView were not directly interchangeable. Overall, percentage gland dropout measurements demonstrated superior diagnostic performance, which would support their use in clinical trials and epidemiology studies, where practicable.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Diagnostic performance of qualitative and quantitative methods of meibomian gland dropout evaluation in dry eye disease: An investigator-masked, randomised crossover study
Michael T M Wang, Barry Power, Ally L Xue, Ji Soo Kim, Jennifer P Craig
Descritores MeSH
- Diagnostic Techniques, Ophthalmological
- Meibomian Glands
- Dry Eye Syndromes
- Male
- Middle Aged
- Prospective Studies
- Tears
- Reproducibility of Results
- Single-Blind Method
- Cross-Over Studies
Veja também
Estudos relacionados
- Avaliação da eficácia do óleo tópico de árvore de chá versus azitromicina livre de conservantes no tratamento da doença ocular seca associada à disfunção da glândula meibomiana: Ensaio controlado randomizado com foco nos níveis de interleucina lacrimal
- Effects of HP-Guar Nano-emulsion Artificial Tears on Symptoms and Severity of Meibomian Gland Dysfunction in Evaporative Dry Eye During a 90-Day Longitudinal Study
- Comparison of different methods to image the tear film before and during contact lens wear
- Temporal changes in parameters associated with tear film stability after instillation of long-acting diquafosol ophthalmic solution in soft contact lens wearers