O que aconteceu

Cone-beam computed tomography (CBCT) is widely used in dentomaxillofacial imaging and radiotherapy but is limited by noise and low contrast resolution. Deep learning (DL) has emerged as a promising tool for CBCT enhancement, improving image quality and diagnostic accuracy. This systematic review and meta-analysis evaluated DL-based techniques for dentomaxillofacial CBCT enhancement and their impact on objective image quality metrics.

A systematic search across six databases identified studies applying DL for CBCT enhancement. Performance metrics included mean absolute error (MAE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and root mean squared error (RMSE). Risk of bias was assessed using the modified QUADAS-2 tool. Meta-analyses were performed using random-effects models, with effect sizes expressed as standardized mean differences (SMD) for MAE and RMSE and mean differences (MD) for PSNR and SSIM. Heterogeneity was evaluated using Cochran's Q and I2 statistics.

O que encontraram

Thirty-seven studies met inclusion criteria, covering CBCT-to-CT synthesis (27), metal artifact reduction (4), noise reduction (3), motion artifact reduction (1), and super-resolution (2). DL significantly reduced MAE (SMD: -4.24, 95% CI: -5.68 to -2.80, p 99%) limits direct comparisons.

Por que isso importa

DL improves CBCT image quality, but methodological variability and limited clinical validation necessitate further research.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Deep learning for dentomaxillofacial cone-beam computed tomography enhancement: A systematic review and meta-analysis

Soroush Sadr, Hossein Mohammad-Rahimi, Ghazal Hemmati, Anita Taheri, Anahita Najafi, Rata Rokhshad, Ruben Pauwels, Falk Schwendicke

Descritores MeSH

  • Maxilla
  • Deep Learning
  • Radiographic Image Enhancement
  • Cone-Beam Computed Tomography
  • Humans
  • Image Processing, Computer-Assisted
  • Signal-To-Noise Ratio

Veja também

Estudos relacionados