ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia de tórax de pulmões saudáveis

Comparison of ventilation with second-generation supraglottic airway devices in a prospective randomized cadaver study

Anestesiologia e Dor
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de tórax de pulmões saudáveis. N.a. Radiology by Dr. Johan Verbeken. Scan and image editing by Vincent Mia Edie Verheyen · domínio público · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaScientific reports21 mai 20260 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Second-generation supraglottic airway devices (SADs) are widely used alternatives to endotracheal intubation in both anesthesia and emergency airway management. The newly developed LT®evo represents a redesigned version of the established Laryngeal Tube Suction Disposable (LTS-D). This study compared the ventilatory performance of the LT®evo with endotracheal intubation and three other second-generation SADs- LTS-D, Ambu® AuraGain™ and i-gel® Plus-using a controlled human cadaver model. In this prospective, randomized experiment, six thawed adult cadavers were sequentially ventilated via an endotracheal tube (ET) and four SADs under standardized mechanical ventilation (tidal volume 7 mL/kg, PEEP 5 cmH₂O, respiratory rate 10/min). Airway pressure and flow were continuously recorded (sampling rate 200 Hz) to determine inspiratory tidal volume, pressure, flow, and calculated resistance. Endotracheal intubation using fiberoptics was attempted via LT®evo , AuraGain™ and i-gel® Plus. Data were analyzed using Kruskal-Wallis tests with Holm-corrected post-hoc pairwise comparisons. From six human cadavers (60-85kg estimated body weight), 30 complete ventilation datasets were obtained. Initial fiberoptic control of SAD placement showed optimal positioning in 13 of 24 insertions. During ventilation cycles, inspiratory tidal volumes of the LT®evo (0.49 [0.46-0.52]) were similar to those of ET, AuraGain™ and LTS-D and superior to those of the i-gel® Plus (0.31 L [0.27-0.33], p < 0.001). Peak inspiratory pressure and inspiratory resistance were higher in ET when compared to LT®evo and all other SADs. Endotracheal intubation using fiberoptics was successful in all attempts via LT®evo , AuraGain™ and i-gel® Plus. In this controlled cadaver study, the newly designed LT®evo demonstrated ventilatory performance comparable to that of the LTS-D and the Ambu® AuraGainTM and was superior to the i-gel® Plus in delivering adequate tidal volumes. Additionally, LT®evo allowed for fiberoptic ET placement. Importantly, these results are specific to the cadaveric model and reflect technical variability in ventilation mechanics rather than clinical effectiveness.Clinical trial numberGerman Clinical Trials Registry, DRKS00038309, on October 30th, 2025.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Comparison of ventilation with second-generation supraglottic airway devices in a prospective randomized cadaver study

Frank Weilbacher, Nikolai Kaltschmidt, Marita Klein, Lisa Kaltschmidt, Harald Genzwürker, Erik Popp, Stephan Katzenschlager

Descritores MeSH

  • Intubation, Intratracheal
  • Respiration, Artificial
  • Airway Management
  • Male
  • Cadaver
  • Tidal Volume
  • Laryngeal Masks
  • Prospective Studies
  • Female
  • Humans

Veja também