Comparison of the efficacy and safety of metallic ureteral stent versus polymer ureteral stent for patients with malignant ureteral obstruction: a meta-analysis of comparative trials
UrologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
This study aimed to evaluate and compare the clinical performance of metallic and polymer ureteral stents in patients with malignant ureteral obstruction (MUO), with a focus on complications and success rates
We conducted a meta-analysis of seven studies, obtained by searching various databases from inception to February 2025, involving patients with MUO treated with metallic or polymer stents. Study quality was assessed using the RoB 2 tool for randomized controlled trials and the ROBINS-I tool for non-randomized studies. Primary outcomes included success rates at 1, 3, 6, and 12 months, and complication rates. Odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using a random-effects model. When data were available, exploratory analyses were performed according to metallic stent type
O que encontraram
The success rates at 3, 6, and 12 months were consistently higher in patients with metal stents (ORs 5.14, 2.70, and 3.67, respectively) than in those with polymer stents. The overall rate of complications did not differ significantly between the two groups; however, a higher risk of complications was observed in studies using covered metallic stents (OR 4.45, 95% CI 1.57–12.62)
Por que isso importa
Compared with polymer ureteral stents, metallic ureteral stents demonstrated higher success rates in patients with MUO, particularly at longer follow-up, albeit with an increased risk of complications. These findings suggest that metallic stents may represent a favorable option in carefully selected patients
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Comparison of the efficacy and safety of metallic ureteral stent versus polymer ureteral stent for patients with malignant ureteral obstruction: a meta-analysis of comparative trials
Jung Hoon Kim, Yun-Jung Yang, Joongwon Choi, Yong Seong Lee, Kyungchan Min, Jong Hyun Tae, Se Young Choi, Eun-Jung Yang, Chung Un Lee
Descritores MeSH
- Ureteral Neoplasms
- Ureteral Obstruction
- Stents
- Polymers
- Humans
- Treatment Outcome
- Metals
- Prosthesis Design
- Ureter
Veja também
Estudos relacionados
- Stents uretéricos metálicos versus poliméricos para obstrução ureteriana maligna crônica: revisão sistemática e metanálise
- Retrograde Ureteral Stents Versus Percutaneous Nephrostomy in the Management of Malignant Ureteral Obstruction: A Systematic Review and Meta-Analysis
- Comparison of different segmental metal ureteral stents as maintenance therapy across different years in ureteral stricture management: a systematic review and meta-analysis
- Randomized Controlled Trial to Evaluate the Efficacy and Safety of Silicone-Covered Metallic Mesh Stent Compared to Conventional Polymeric Stent in Malignant Ureteral Obstruction Patients