Comparison of posterior cruciate retention and substitution in total knee arthroplasty during gait: a systematic review and meta-analysis
OrtopediaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
To compare the gait patterns between posterior cruciate retention and substitution in total knee arthroplasty (TKA).
Electronic databases including the PubMed, Embase, CINAHL, Web of Science, and Cochrane databases were searched to identify clinical trials investigating posterior cruciate retention versus substitution in TKA. The outcome measurements were the kinematic gait parameters (flexion at heel strike, maximum flexion during loading response, flexion range during loading, minimal flexion at terminal stance, maximal flexion at the swing, and total flexion during the gait cycle), Knee Society Score (KSS), knee flexion, knee extension, and walking speed. Statistical software Review Manager 5.4 and Stata 14.0 were used for data analysis.
O que encontraram
There were finally 9 studies included in this meta-analysis. The results did not reveal differences between posterior cruciate retention (CR) and posterior cruciate substitution (PS) groups in TKA, in terms of kinematic gait parameters, knee extension, walking speed, and KSS. However, the PS group had a significantly larger knee flexion angle than that in the CR group [weighted mean difference = - 3.20, 95% CI - 6.13 to - 0.28, P = 0.03].
Por que isso importa
Both the posterior cruciate retention and posterior cruciate substitution lead to obvious improvements in patient function and have their advantages in getting a good cup position. The PS design is significantly better on the knee flexion, while there are no statistical differences in kinematic gait parameters and outcome scores between them. This might indicate that surgeons do not necessarily need a PS design to substitute the posterior cruciate ligament during TKA.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Comparison of posterior cruciate retention and substitution in total knee arthroplasty during gait: a systematic review and meta-analysis
Chunjiang Li, Mingjie Dong, Dinglong Yang, Zhiqiang Zhang, Junjun Shi, Ruipeng Zhao, Xiaochun Wei
Descritores MeSH
- Posterior Cruciate Ligament Reconstruction
- Gait
- Posterior Cruciate Ligament
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
- Knee Prosthesis
- Biomechanical Phenomena
- Range of Motion, Articular
- Humans
- Knee Joint
Veja também
Estudos relacionados
- Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs
- PCL retained is safe in medial pivot TKA-a prospective randomized trial
- Fluoroscopic and radiostereometric analysis of a bicruciate-retaining versus a posterior cruciate-retaining total knee arthroplasty: a randomized controlled trial
- A prospective comparison of total knee arthroplasty using ultra-congruent, condylar-stabilizing, and posterior-stabilized devices implanted with kinematic alignment: better 2-year outcomes with ultra-congruent