
Comparison of comfort and complications of Implantable Venous Access Port (IVAP) with ultrasound guided Internal Jugular Vein (IJV) and Axillary Vein/Subclavian Vein (AxV/SCV) puncture in breast cancer patients: a randomized controlled study
OncologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Axillary vein/subclavian vein (AxV/SCV) and Internal jugular vein (IJV) are commonly used for implantable venous access port (IVAP) implantation in breast cancer patients for chemotherapy. Previous research focused on comparison of complications while patient comfort was ignored. This study aims to compare patient comfort, surgery duration and complications of IVAP implantation between IJV and AxV/SCV approaches.
Two hundred forty-eight breast cancer patients were enrolled in this randomized controlled study from August 2020 to June 2021. Patients scheduled to undergo IVAP implantation were randomly and equally assigned to receive central venous catheters with either AxV /SCV or IJV approaches. All patients received comfort assessment using a comfort scale table at day 1, day 2 and day 7 after implantation. Patient comfort, procedure time of operation as well as early complications were compared.
O que encontraram
Patient comfort was significantly better in the AxV/SCV group than that of IJV group in day 1 (P < 0.001), day 2 (P < 0.001) and day 7(P = 0.023). Procedure duration in AxV/SCV group was slightly but significantly shorter than IJV group (27.14 ± 3.29 mins vs 28.92 ± 2.54 mins, P < 0.001). More early complications occurred in AxV/SCV group than IJV group (11/124 vs 2/124, P = 0.019). No difference of complications of artery puncture, pneumothorax or subcutaneous hematoma between these two groups but significantly more catheter misplacement in AxV/SCV group than IJV group (6/124 vs 0/124, P = 0.029). Absolutely total risk of complications was rather low in both groups (8.87% in AxV/SCV group and 1.61% in IJV group).
Por que isso importa
Our study indicates that patients with AxV/SCV puncture have higher comfort levels than IJV puncture. AxV/SCV puncture has shorter procedure duration but higher risk of early complications, especially catheter misplacement. Both these two approaches have rather low risk of complications. Consequently, our study provides an alternative choice for breast cancer patients to reach better comfort.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Comparison of comfort and complications of Implantable Venous Access Port (IVAP) with ultrasound guided Internal Jugular Vein (IJV) and Axillary Vein/Subclavian Vein (AxV/SCV) puncture in breast cancer patients: a randomized controlled study
Yan Bo Chen, Hao Shi Bao, Ting-Ting Hu, Zhou He, Biaolin Wen, Feng-Tao Liu, Feng Xi Su, He Ran Deng, Jian Nan Wu
Descritores MeSH
- Breast Neoplasms
- Catheterization, Central Venous
- Patient Satisfaction
- Punctures
- Central Venous Catheters
- Adult
- Middle Aged
- Subclavian Vein
- Time Factors
- Ultrasonography, Interventional
Veja também
Estudos relacionados
- Comparison of ultrasound guided supraclavicular subclavian vein versus infraclavicular subclavian/axillary vein catheterization: A systematic review and meta analysis
- Ultrasound-guided central venous catheterization around the neck: Systematic review and network meta-analysis
- Ultrasound guided axillary vein catheterization versus subclavian vein cannulation with landmark technique: A PRISMA-compliant systematic review and meta-analysis
- Axillary versus Jugular Vein for Totally Implanted Port-A-Cath, Randomized, Controlled Trial