Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model
CirurgiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Traditional surgical training methods such as "learning-by-doing" raise ethical and methodological concerns. To improve training and reduce patient risk, a 3D-printed LLETZ simulator was developed. While initial studies showed advantages over a conventional model, they were limited to medical students and lacked comparison with a commercially available simulator.
A single-center study was conducted at the University Hospital Wuerzburg. 60 medical students without prior LLETZ experience and 10 gynecology residents with prior exposure were randomly assigned to train on either a commercial or the novel in-house simulator. Each participant performed five electrosurgical excisions. Performance was evaluated using LEEP scores, resection status (R0 resections), and blinded video assessments by two senior clinicians. Additionally, participants completed questionnaires, to capture subjective training impressions.
O que encontraram
The in-house simulator demonstrated superior performance compared to the commercial model. When analyzed separately, changes in LEEP scores over the five attempts were statistically significant for both simulators. The effect size was larger for the in-house simulator (η2 = 0.227) than for the conventional simulator (η2 = 0.10). Within-group analysis revealed no significant pairwise differences across all attempts for the commercial simulator. In contrast, several pairwise comparisons remained statistically significant for the in-house simulator (attempts 1 vs. 3, 1 vs. 4, 2 vs. 5, and 1 vs. 5), all with large effect sizes (Cohen's d > 1.1). Between-group comparison of individual LEEP scores showed a statistically significant difference in the fifth attempt (p = 0.002), with a large effect size (Cohen's d = 1.01) favoring the in-house simulator. Higher R0 resection rates were observed with the in-house simulator in the third (100% vs. 83.3%) and fourth attempts (96.7% vs. 73.3%). Blinded video assessments by two senior experts confirmed these findings, demonstrating higher checklist, Global Rating Scale (GRS), and overall mean scores for the in-house simulator from the third attempt onward (all p 0.8). Participant feedback further supported these results, indicating improved confidence, technical skills, and perceived educational value.
Por que isso importa
This study demonstrated that the novel in-house 3D-printed simulator significantly outperformed the commercial model in objective surgical performance, learning progression and user satisfaction.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model
Anne Cathrine Scherer-Quenzer, Katharina Reinhart, Joachim Diessner, Anastasia Altides, Johanna Buechel, Bettina Blau-Schneider, Stephanie Tina Sauer, Barbara Deschler-Baier, Achim Woeckel, Matthias Kiesel
Descritores MeSH
- Simulation Training
- Gynecologic Surgical Procedures
- Printing, Three-Dimensional
- Female
- Gynecology
- Humans
- Internship and Residency
- Clinical Competence
- Cost-Benefit Analysis
Veja também
Estudos relacionados
- Interdisciplinary Simulation Courses to Train Residents on Communication of Unexpected Complications from Perioperative Care: A Randomized Comparison of Within-Event (Microdebriefing) and Postscenario Debriefing
- Procedure-specific simulation for vaginal surgery training: A randomized controlled trial
- A Cost-Effective, Three-Dimensionally Printed Simulation Model Facilitates Learning of Bilobed and Banner Flaps for Mohs Nasal Reconstruction: A Pilot Study
- What is the impact of simulation on the learning of hysteroscopic skills by residents and medical students? A systematic review