Total knee arthroplasty (TKA) is an effective procedure for pain relief and restoration of function in patients with symptomatic end-stage knee arthritis. Kinematic problems due to conventional implant design have been postulated. The objective of this study is to determine if there was any difference in postoperative ROM and outcomes between patients undergoing MP-TKA vs PS-TKA.
We prospectively colected the records of 600 consecutive patients with TKA performed by six senior orthopaedic surgeons between 2017 - 2021. We compared the ROM and patient-reported outcomes (Western Ontario McMaster Osteoarthritis Index WOMAC, Oxford Knee Score OKS, Knee Society Score KSS, Forgotten Joint Score FJS) between MP TKA and PS TKA.
O que encontraram
There were no specific criteria for implant selection as the two groups were consecutive cohorts of patients and implant selection depended on surgeon preference. Demographics, comorbidities, diagnosis and severity of osteoarthritis were similar between MP and PS groups. The trend for OKS in our study is the same in both groups, but with higher mean values in the MP group. The trend of WOMAC pain, stiffness and disability score is the same in both groups, but with higher mean values in the PS group at one year and two years. KSS clinical and functional score is the same in both groups, but with higher mean values in the MP group. The most important score is forgetten joint score which is favourable for the MP group.
Por que isso importa
The patients who underwent the MP-TKA scored better than those who underwent the PS-TKA, particularly regarding deep knee flexion and stability of the prosthesis. This may be related to better replication of natural knee kinematics with MP-TKA.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Comparative study of outcomes with total knee arthroplasty: medial pivot prosthesis vs posterior stabilized implant. Prospective randomized control
Bogdan Obada, Madalina Gabriela Iliescu, Dan Ovidiu Costea, Lucian Petcu, Andrei Ion Popescu
Descritores MeSH
- Knee Prosthesis
- Prosthesis Design
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
- Knee Joint
- Male
- Patient Reported Outcome Measures
- Prospective Studies
- Range of Motion, Articular
- Treatment Outcome
Veja também
Estudos relacionados
- Medial pivot designs result in improved patient reported outcome measures and range of motion when compared to cruciate retaining total knee replacements: A systematic review and meta-analysis
- Fixed- versus Mobile-Bearing Knee Arthroplasty: A Randomized Trial With a Minimum of 10-Year Follow-Up
- Effect of patient specific instruments compared with conventional instruments in total knee arthroplasty : a randomized controlled trial
- A Prospective, Single-Center, Randomized Controlled Study Comparing Non-Resurfacing versus Resurfacing in a Cohort of 250 Posterior-Stabilized Total Knee Arthroplasty With a Minimum Five-Year Follow-Up