Comparação fisiológica de oxigênio de alto fluxo via tubo endotraqueal e estratégias de peça T durante ensaios respiratórios espontâneos: estudo cruzado randomizado

Pneumologia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de tórax de pulmões saudáveis. N.a. Radiology by Dr. Johan Verbeken. Scan and image editing by Vincent Mia Edie Verheyen · domínio público · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaCritical care (London, England)18 ago 20261 citações

Por ScienceMed · · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The optimal spontaneous breathing trial (SBT) strategy remains uncertain because commonly used approaches involve distinct physiological trade-offs. Pressure support ventilation (PSV) may reduce inspiratory effort, whereas T-piece trials more closely approximate unsupported breathing after extubation. Neither approach has shown clear superiority for extubation outcomes. High-flow oxygen (HFO) delivered via endotracheal tube has been proposed as an alternative SBT strategy, but the physiological effects remain insufficiently defined.

In a randomized crossover physiological study, patients receiving mechanical ventilation for at least 24 h and deemed ready for weaning underwent five SBT conditions: T-piece and four HFO via endotracheal tube settings combining two interfaces with different expiratory port diameters (9.8 and 6.9 mm) and two flow rates (40 and 60 L/min). Airway and esophageal pressures, respiratory variables, and electrical impedance tomography parameters were measured during baseline mechanical ventilation and under each SBT condition. Esophageal pressure was also measured after extubation for comparison with post-extubation inspiratory effort. A complementary bench study assessed 24 simulated conditions across four interface diameters and six flow rates.

ClinicalTrials.gov (NCT06816706). Registered on 6 February 2025.

O que encontraram

Twenty patients were analyzed. Compared with T-piece, HFO-6.9 at 60 L/min produced the largest increases in mean expiratory airway pressure (median paired difference, 7.0 cm H2O [95% CI, 6.7-7.4]) and PEEP (6.0 cm H2O [5.8-6.1]). HFO-6.9 at 60 L/min also attenuated global end-expiratory lung volume loss (321 mL [267-523]), reduced dynamic transpulmonary driving pressure (3.3 cm H2O [1.8-4.1]), improved PaO2/FiO2 (28 mmHg [14-52]), and reduced respiratory rate (2 breaths/min [1-4]) compared with T-piece. No statistically significant difference in ΔPes was observed across the five SBT conditions and post-extubation measurements (p = 0.24). Bench simulations supported the flow- and diameter-dependent pressure effects.

Por que isso importa

During SBT, HFO via endotracheal tube generated flow- and expiratory port diameter-dependent increases in airway pressure and lung volume, with lower dynamic transpulmonary driving pressure and improved oxygenation; no statistically significant difference in ΔPes was observed across HFO, T-piece, and post-extubation measurements. These findings support tracheal HFO as a physiologically distinct SBT strategy that may inform individualized SBT selection. Its relationship to clinical outcomes requires further evaluation.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Physiological comparison of high-flow oxygen via endotracheal tube and T-piece strategies during spontaneous breathing trials: a randomized crossover study

Shan-Shan Xu, Rui-Zhi Zhang, Jun-Tong Liu, Lin Wang, Meng-Xue Hou, Xu An, Ming-Yue Miao, Hong-Liang Li, Yue-Fu Wang, Jian-Xin Zhou

Descritores MeSH

  • Intubation, Intratracheal
  • Oxygen
  • Oxygen Inhalation Therapy
  • Male
  • Middle Aged
  • Respiration, Artificial
  • Ventilator Weaning
  • Aged
  • Cross-Over Studies
  • Female

Veja também

Estudos relacionados