O que aconteceu

We reviewed relevant syphilis diagnostic literature and conducted a meta-analysis to address the question, "What is the sensitivity and specificity of the Syphilis Health Check, a rapid qualitative test for the detection of human antibodies to Treponema pallidum." The Syphilis Health Check is the only rapid syphilis test currently cleared by the Food and Drug Administration (FDA). We conducted a systematic review and a meta-analysis using Bayesian bivariate random-effects and fixed-effect models to create pooled estimates of sensitivity and specificity of the Syphilis Health Check. We identified 5 test evaluations published in the literature and 10 studies submitted to the FDA and for a Clinical Laboratory Improvement Amendments waiver application. The pooled sensitivity (95% CI) from the laboratory evaluations (n = 5) was 98.5% (92.1-100%), while pooled specificity was 95.9% (81.5-100.0%). The pooled sensitivity for prospective studies (n = 10) was 87.7% ( 71.8-97.2%), while pooled specificity was 96.7% (91.9-99.2%). Using nontreponemal supplemental testing, the sensitivity improved to a pooled sensitivity of 97.0% (94.8-98.6%). The Syphilis Health Check may provide accurate detection of treponemal antibody.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Clinical Test Performance of a Rapid Point-of-Care Syphilis Treponemal Antibody Test: A Systematic Review and Meta-analysis

Claire C Bristow, Jeffrey D Klausner, Anthony Tran

Descritores MeSH

  • Syphilis
  • Bayes Theorem
  • Humans
  • Prospective Studies
  • Sensitivity and Specificity
  • Syphilis Serodiagnosis
  • Treponema pallidum
  • Antibodies, Bacterial
  • Point-of-Care Systems

Veja também

Estudos relacionados