ScienceMed®
Imagem de arquivo, ilustrativa: Fibras de músculo esquelético dissociadas, ao microscópio óptico

Clinical outcomes for grades III-V acromioclavicular dislocations favor double-button fixation compared to clavicle hook plate fixation: a systematic review and meta-analysis

Ortopedia
Imagem de arquivo, ilustrativa — não é do estudo. Fibras de músculo esquelético dissociadas, ao microscópio óptico. Berkshire Community College Bioscience Image Library · CC0 · Wikimedia Commons

MetanáliseNível 1 · Evidência consolidadaEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie25 fev 202311 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

The purpose of this study was to perform a systematic review and meta-analysis of both randomized controlled and observational studies comparing double-button suture fixation to hook plate fixation for types III-IV acromioclavicular joint dislocation.

Systematic review of Medline, Embase, Scopus, and Google Scholar, including all levels 1-3 studies from 2000 to 2022. Clinical outcome scores, range of motion, and complications were included. Risk of bias was assessed using the Cochrane Collaboration's ROB2 tool and ROBINs-I tool. MINORS and modified Coleman Methodology Score (CMS) were used to assess within study quality. The GRADE system was used to assess the overall quality of the body of evidence. Heterogeneity was assessed using χ2 and I2 statistics.

Level III; systematic review and meta-analysis.

O que encontraram

Fifteen studies were included. Three of the four included LOE II and eleven of the LOE III studies had a high risk of bias. Study quality was considered poor and fair for 67% by MINORS criteria and 93% for CMS criteria. The pooled estimate (SMD 0.662) for all clinical outcomes was statistically significant and in favor of button repair (p = 0.0001). The pooled estimate (SMD 0.662) for all VAS pain scores was statistically significant, again in favor of button repair (p = 0.001).

Por que isso importa

The results of this meta-analysis demonstrated significantly better outcomes of button repair for acute ACJ dislocations when compared to clavicle hook plate. Button repair is also associated with a 2.2 times lower risk for complications. However, risk of bias is high, and study quality within and between studies was low. These results, therefore, must be viewed with caution.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Clinical outcomes for grades III-V acromioclavicular dislocations favor double-button fixation compared to clavicle hook plate fixation: a systematic review and meta-analysis

Erik Hohmann, Kevin Tetsworth

Descritores MeSH

  • Joint Dislocations
  • Shoulder Dislocation
  • Acromioclavicular Joint
  • Humans
  • Randomized Controlled Trials as Topic
  • Treatment Outcome
  • Observational Studies as Topic
  • Bone Plates
  • Clavicle

Veja também

Estudos relacionados