Capnographic monitoring using a novel mainstream system during endoscopic ultrasound and endoscopic retrograde cholangiopancreatography: A prospective randomized controlled trial
Anestesiologia e DorPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Insufficient studies exist on capnography efficacy during endoscopic ultrasound or endoscopic retrograde cholangiopancreatography, and no definitive conclusions have been drawn. To evaluate the feasibility and efficacy of a novel mainstream capnography using an over-the-biteblock end-tidal CO2 (EtCO2) detector in decreasing the risk of hypoxemia during endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP).
Patients undergoing EUS or ERCP with conscious sedation at a single Japanese center were randomized to a control or a novel capnography monitored (intervention) group in a 1:1 ratio. Hypoxemia correction maneuvers were pursued if the oxygen saturation decreased to <92% in the control or intervention group and if a 15-s suspension of EtCO2 wave occurred in the intervention group. The primary outcome was the incidence of hypoxemic events, defined as oxygen saturation <90%, during the procedures. Secondary outcomes included technical feasibility of EUS and ERCP with the use of this novel over-the-biteblock monitor.
O que encontraram
In total, 250 patients were enrolled without dropouts or missing data (control group: 125; capnography group: 125). There was no significant difference in the incidence of hypoxemia between the control and capnography groups (29.6% [37/125] vs. 26.4% [33/125]; p = .573). The estimated odds ratio was 0.925 (95% confidence interval: 0.708-1.208). The EtCO2 concentration was successfully captured without impeding endoscopic maneuvers from the beginning to the end of the procedure in all patients.
Por que isso importa
Although the novel mainstream capnography with an over-the-biteblock EtCO2 detector captures the EtCO2 concentration in EUS or ERCP under conscious sedation, it does not lead to the prevention of hypoxemia.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Capnographic monitoring using a novel mainstream system during endoscopic ultrasound and endoscopic retrograde cholangiopancreatography: A prospective randomized controlled trial
Yoichi Takimoto, Eisuke Iwasaki, Masayasu Horibe, Seiichiro Fukuhara, Kazuhiro Minami, Shintaro Kawasaki, Tatsuhiro Masaoka, Haruhiko Ogata, Fateh Bazerbachi, Takanori Kanai
Descritores MeSH
- Hypoxia
- Cholangiopancreatography, Endoscopic Retrograde
- Monitoring, Intraoperative
- Endosonography
- Capnography
- Aged
- Middle Aged
- Monitoring, Physiologic
- Prospective Studies
- Male
Veja também
Estudos relacionados
- Capnography monitoring in procedural intravenous sedation: a systematic review and meta-analysis
- Covered self-expandable metal stents in benign biliary strictures caused by chronic pancreatitis: a randomized controlled trial of 6 versus 12 months of stenting
- Capnography With Integrated Pulmonary Index for Preventing Hypoxemia During Pediatric Urologic Surgery Under Sedation: A Randomized Controlled Trial
- A prospective, randomized, single-blinded study comparing the efficacy and safety of dexmedetomidine and propofol for sedation during endoscopic retrograde cholangiopancreatography
- Efeito da Endoscopia COMBO de Vias Aéreas Orofaríngeas versus Cânula Nasal Convencional sobre Hipoxemia em Pacientes Obesos em Fase de Endoscopia Gastrointestinal Sob Sedação: Ensaio Controlado Randomizado