Biomechanical analysis of fixation methods in acetabular fractures: a systematic review of test setups
OrtopediaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
Optimal anatomical reduction and stable fixation of acetabular fractures are important in avoiding secondary dislocation and osteoarthritis. Biomechanical studies of treatment options of acetabular fractures aim to evaluate the biomechanical properties of different fixation methods. As the setup of the biomechanical test can influence the experimental results, this review aimed to analyze the characteristics, comparability and clinical implications of studies on biomechanical test setups and finite element analyses in the fixation of acetabular fractures.
A systematic literature research was conducted according to the PRISMA guidelines, using the PubMed/MEDLINE and Web of Science databases. 44 studies conducting biomechanical analyses of fixation of acetabular fractures were identified, which met the predefined inclusion and exclusion criteria and which were published in English between 2000 and April 16, 2021. The studies were analyzed with respect to distinct parameters, including fracture type, material of pelvis model, investigated fixation construct, loading direction, loading protocol, maximum loading force, outcome parameter and measurement method.
O que encontraram
In summary, there was no standardized test setup within the studies on fixation constructs for acetabular fractures. It is therefore difficult to compare the studies directly, as they employ a variety of different test parameters. Furthermore, the clinical implications of the biomechanical studies should be scrutinized, since several test parameters were not based on observations of the human physiology.
Por que isso importa
The limited comparability and restricted clinical implications should be kept in mind when interpreting the results of biomechanical studies and when designing test setups to evaluate fixation methods for acetabular fractures.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Biomechanical analysis of fixation methods in acetabular fractures: a systematic review of test setups
Nico Hinz, Julius Dehoust, Matthias Münch, Klaus Seide, Tobias Barth, Arndt Peter Schulz, Karl-Heinz Frosch, Maximilian J Hartel
Descritores MeSH
- Hip Fractures
- Spinal Fractures
- Fractures, Bone
- Bone Screws
- Acetabulum
- Humans
- Fracture Fixation, Internal
- Biomechanical Phenomena
- Bone Plates
Veja também
Estudos relacionados
- Use of 3D printing and pre-contouring plate in the surgical planning of acetabular fractures: A systematic review
- A systemic review and meta-analysis of pararectus versus ilioinguinal approach for the management of acetabular fractures
- Indications, complications, and clinical outcomes of fixation and acute total hip arthroplasty for the treatment of acetabular fractures: A systematic review
- Total hip arthroplasty in acute acetabulum fractures: a systematic review
- Análise de elementos finitos da biomecânica pé-insolo para desenho de palmilhas: uma revisão sistemática