O que aconteceu

The resection of lymph nodes/neck dissection is a typical part of the surgical treatment of head and neck malignancies. The aim of this study was to compare subcutaneous closure using single knotted, braided suture (VicrylTM, standard arm) with continuous self-locking, monofilament barbed suture (V-LocTM, experimental arm).

Neck Lock was a randomized clinical trial at a single tertiary referral center. It was conducted from 2016 till 2022 with a follow-up period of 3 months. Assessment of safety and aesthetic outcome was double-blinded. 68 patients were randomized after application of exclusion criteria. Subcutaneous wound closure was performed in an intrapatient randomized fashion for suture technique. The primary endpoint was the duration of subcutaneous sutures. Wound healing and scar formation were recorded at multiple postoperative intervals as secondary endpoints.

The trial was registered with WHO acknowledged primary registry "German Clinical Trials Register" under the ID DRKS00025831 ( https://drks.de/search/de/trial/DRKS00025831 ).

O que encontraram

The median age was 61 years, 89.7% were male. 92.6% suffered from a squamous cell carcinoma. There was a significant difference in median subcutaneous suture time (p = 0.024) between the experimental (6:11 ± 2:30 min) and standard (7:01 ± 2.42 min) arms. There was no significant difference in safety when assessing adverse events (AEs). At least one AE occurred in 14.7% vs. 5.9%, for barbed and smooth sutures respectively (p = 0.16).

Por que isso importa

For neck dissection of head and neck malignancies, subcutaneous wound closure with self-locking sutures offers significant time savings over the single knot technique with similar safety and aesthetic results.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Barbed suture in neck dissection: a randomized clinical study on efficacy, safety and aesthetic outcome

Johannes Doescher, Benjamin Emmanuel, Jens Greve, Patrick J Schuler, Fabian Sommer, Simon Laban, Johannes Veit, Thomas K Hoffmann

Descritores MeSH

  • Sutures
  • Esthetics
  • Suture Techniques
  • Neck Dissection
  • Double-Blind Method
  • Female
  • Head and Neck Neoplasms
  • Adult
  • Male
  • Middle Aged

Veja também

Estudos relacionados