Applications of different energy devices in laparoscopic and robotic gynecological surgery: a systematic review
CirurgiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
This study aims to evaluate and summarize the existing literature regarding the safety, efficacy, and outcomes of various energy sources in minimally invasive gynecological surgeries.
A systematic review was conducted by searching the PubMed/MEDLINE, Cochrane Library, and Web of Science databases. We included studies that compared different energy sources used in laparoscopic and robotic gynecological surgeries, focusing on their advantages and complications. 37 studies were ultimately included in this review.
O que encontraram
Among the 37 studies, 24 were randomized controlled trials, 11 were retrospective studies, and 1 was prospective. In laparoscopic procedures, advanced energy sources were associated with reduced intraoperative blood loss and shorter operative times. Specifically, ultrasonic devices demonstrated significantly less thermal damage and facilitated easier postoperative histologic assessment of lymph nodes compared to conventional electrosurgery. In robotic assisted surgeries, the literature reported shorter hospital stays and reduced thermal injury during colpotomy when utilizing laser energy. No significant differences were observed in other perioperative outcomes across both minimally invasive approaches.
Por que isso importa
Advanced energy devices may offer advantages in gynecological minimally invasive surgery, particularly in minimizing tissue trauma and enhancing surgical precision. However, evidence on outcomes such as lateral thermal spread and tissue healing remains limited and inconsistent. Further high-quality comparative studies are needed to clarify the clinical implications of each energy source and guide optimal instrument selection, especially in robotic assisted procedures.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Applications of different energy devices in laparoscopic and robotic gynecological surgery: a systematic review
Tiago Meneses Alves, Luís Ferreira De Castro, António Tomé, Helder Ferreira
Descritores MeSH
- Robotic Surgical Procedures
- Laparoscopy
- Gynecologic Surgical Procedures
- Length of Stay
- Operative Time
- Electrosurgery
- Blood Loss, Surgical
- Female
- Humans
Veja também
Estudos relacionados
- Comparação dos resultados perioperatórios para cirurgia robótica da Vinci assistida, laparoscópica e aberta em procedimentos oncológicos: revisão sistemática da literatura e metanálise de evidências da China
- Eficácia comparativa e segurança da ressecção hepática robótica versus laparoscópica para doenças hepáticas benignas: revisão sistemática e meta-análise
- Ressecção robótica totalmente baixa anterior versus cirurgia laparoscópica convencional para câncer de reto: revisão sistemática e metanálise
- Hepatectomia robótica para doença hepática benigna: séries consecutivas de um único centro e metanálise comparando abordagens minimamente invasivas e abertas