ScienceMed®
Imagem de arquivo, ilustrativa: Radiografia de tórax de pulmões saudáveis

Anesthesia considerations to reduce motion and atelectasis during advanced guided bronchoscopy

Pneumologia
Imagem de arquivo, ilustrativa — não é do estudo. Radiografia de tórax de pulmões saudáveis. N.a. Radiology by Dr. Johan Verbeken. Scan and image editing by Vincent Mia Edie Verheyen · domínio público · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaBMC pulmonary medicine17 jul 2021104 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Partnership between anesthesia providers and proceduralists is essential to ensure patient safety and optimize outcomes. A renewed importance of this axiom has emerged in advanced bronchoscopy and interventional pulmonology. While anesthesia-induced atelectasis is common, it is not typically clinically significant. Advanced guided bronchoscopic biopsy is an exception in which anesthesia protocols substantially impact outcomes. Procedure success depends on careful ventilation to avoid excessive motion, reduce distortion causing computed tomography (CT)-to-body-divergence, stabilize dependent areas, and optimize breath-hold maneuvers to prevent atelectasis. Herein are anesthesia recommendations during guided bronchoscopy. An FiO2 of 0.6 to 0.8 is recommended for pre-oxygenation, maintained at the lowest tolerable level for the entire the procedure. Expeditious intubation (not rapid-sequence) with a larger endotracheal tube and non-depolarizing muscle relaxants are preferred. Positive end-expiratory pressure (PEEP) of up to 10-12 cm H2O and increased tidal volumes help to maintain optimal lung inflation, if tolerated by the patient as determined during recruitment. A breath-hold is required to reduce motion artifact during intraprocedural imaging (e.g., cone-beam CT, digital tomosynthesis), timed at the end of a normal tidal breath (peak inspiration) and held until pressures equilibrate and the imaging cycle is complete. Use of the adjustable pressure-limiting valve is critical to maintain the desired PEEP and reduce movement during breath-hold maneuvers. These measures will reduce atelectasis and CT-to-body divergence, minimize motion artifact, and provide clearer, more accurate images during guided bronchoscopy. Following these recommendations will facilitate a successful lung biopsy, potentially accelerating the time to treatment by avoiding additional biopsies. Application of these methods should be at the discretion of the anesthesiologist and the proceduralist; best medical judgement should be used in all cases to ensure the safety of the patient.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Anesthesia considerations to reduce motion and atelectasis during advanced guided bronchoscopy

Michael A Pritchett, Kelvin Lau, Scott Skibo, Karen A Phillips, Krish Bhadra

Descritores MeSH

  • Anesthesia, General
  • Pulmonary Atelectasis
  • Bronchoscopy
  • Intraoperative Complications
  • Lung
  • Breath Holding
  • Positive-Pressure Respiration
  • Humans
  • Tomography, X-Ray Computed

Veja também

Estudos relacionados