ScienceMed®
Imagem de arquivo, ilustrativa: Íris humana em fotografia macro

An Evaluation of the Efficacy and Safety of Timolol Maleate 0.5% Microdrops Administered with the Nanodropper

Oftalmologia
Imagem de arquivo, ilustrativa — não é do estudo. Íris humana em fotografia macro. Kamil Saitov · CC BY 4.0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaOphthalmology14 mar 20246 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

To examine if 12.5 μl timolol maleate 0.5% microdrops dispensed with the Nanodropper Adaptor provide noninferior intraocular pressure (IOP) reduction compared with conventional 28 μl drops in patients with open-angle glaucoma (OAG) and ocular hypertension (OHT).

Prospective, noninferiority, parallel, multicenter, single-masked, active-controlled, randomized trial.

Treatment-naïve subjects who were recently diagnosed with OAG and OHT at the Aravind Eye Care System.

Both eyes of subjects received 1 commercially available drop or both eyes of subjects received 1 microdrop of timolol maleate 0.5%. We measured IOP, resting heart rate (HR), and blood pressure (BP) at baseline and 1, 2, 5, and 8 hours after timolol administration.

Proprietary or commercial disclosure may be found after the references.

O que encontraram

The IOP was the primary outcome measure. Secondary outcomes were resting HR, systolic BP (sBP), and diastolic BP (dBP).

Adaptor-mediated microdrops and conventional drops of timolol significantly decreased IOP compared with baseline at all timepoints. Noninferiority was established at 3 of 4 timepoints. Heart rate decreases with Nanodropper were approximately 3 beats per minute (bpm) less than with conventional drops.

Por que isso importa

Timolol microdrops appear to be as effective in ocular hypotensive action as conventional drops with a slightly attenuated effect on resting HR and BP.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

An Evaluation of the Efficacy and Safety of Timolol Maleate 0.5% Microdrops Administered with the Nanodropper

Jennifer S Steger, Indira Durai, Annamalai Odayappan, Ramalakshmi Raman, Talla Sruthi, Allisa J Song, George Puthuran, Rengaraj Venkatesh, Elizabeth Colantuoni, Alan L Robin

Descritores MeSH

  • Glaucoma, Open-Angle
  • Ocular Hypertension
  • Ophthalmic Solutions
  • Heart Rate
  • Timolol
  • Tonometry, Ocular
  • Blood Pressure
  • Intraocular Pressure
  • Antihypertensive Agents
  • Adult

Veja também

Estudos relacionados