O que aconteceu

The design of tibial trays for total knee arthroplasty (TKA) has been a topic of research for several decades. Although all-polyethylene trays were developed to address issues such as osteolysis and to enhance the longevity of the prosthesis, as well as knee range of motion, metal-backed designs have remained the most commonly used type of prosthesis. This meta-analysis aimed to compare the clinical, radiological, and survival outcomes of both designs.

Five databases were searched from inception until October 1, 2020, for randomized controlled trials (RCTs) that compared the outcomes of all-polyethylene and metal-backed tibial components in TKA. The outcomes of interest included range of motion, knee society score, stairs climbing scores, radiostereographic analysis, survivorship and complication. This review was conducted in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Risk of bias was assessed using the Newcastle-Ottawa tool.

I.

O que encontraram

A total of 14 RCTs with 1367 TKA were included with a mean age of - years and - years for all-polyethylene and metal-backed tibial components groups, respectively. All-polyethylene group demonstrated statistically significant differences in five-year survivorship (OR 0.27; 95% CI 0.10-0.75; p value 0.01) and stairs climbing score (OR - 2.07; 95% CI - 3.27-0.87; p value 0.0007) when compared to the metal-backed group. The metal-backed design was significantly more radiographically stable in anterior-posterior, varus-valgus, and internal-external rotations at the 2-year follow-up compared to all-polyethylene tibias (OR - 0.09; 95% CI - 0.16 to - 0.02; p value 0.02) as per the pooled radiostereographic analysis. However, ten-year survivorship (OR 0.92; 95% CI 0.53-1.60; p value 0.78), range of motion (OR - 0.57; 95% CI - 2.00-0.85, p value 0.43), knee society scores (OR 1.38; 95% CI - 0.47-3.23, p value 0.14), and complications (OR 0.83; 95% CI 0.5-1.39, p value 0.48) were comparable between both groups.

Por que isso importa

While this meta-analysis suggests that all-polyethylene tibial components in total knee arthroplasty may offer advantages over metal-backed components in terms of five-year survivorship, and stairs climbing score, this finding should be considered in the context of potential confounding factors. Nonetheless, based on the results, the all-polyethylene implant should be considered a viable choice for primary knee replacement.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials

Aissam Elmhiregh, Yousef Abuodeh, Osama Alzobi, Bashir Zikria, Mohd Alkhayarin, Bernard F Morrey

Descritores MeSH

  • Arthroplasty, Replacement, Knee
  • Knee Prosthesis
  • Metals
  • Prosthesis Design
  • Prosthesis Failure
  • Tibia
  • Randomized Controlled Trials as Topic
  • Humans
  • Polyethylene
  • Knee Joint

Veja também

Estudos relacionados