ScienceMed®
Imagem de arquivo, ilustrativa: Corte anatômico do pé mostrando a trama do osso esponjoso (1906)

Ajuste dentro do dispositivo de exposição e alteração do tamanho do voxel na medida do osso alveolar CBCT para planejamento do implante: uma revisão sistemática

Medicina
Imagem de arquivo, ilustrativa — não é do estudo. Corte anatômico do pé mostrando a trama do osso esponjoso (1906). American Practice of Surgery (1906), via Internet Archive · domínio público · Wikimedia Commons

Revisão sistemáticaNível 1 · Evidência consolidadaTomography (Ann Arbor, Mich.)9 nov 20260 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

This review examined whether within-device exposure-setting or nominal voxel-size changes in cone-beam computed tomography (CBCT) affect linear alveolar bone measurements for implant planning, separating accuracy from agreement.

Database-specific search strategies and retrieval counts are reported for PubMed/MEDLINE, Ovid Embase, Scopus, and Web of Science Core Collection. Study selection is presented in the updated PRISMA flow diagram. The reported International Prospective Register of Systematic Reviews (PROSPERO) identifier is CRD420261361509. Studies were grouped by outcome, protocol contrast, and experimental model. The Quality Assessment Tool for In Vitro Studies (QUIN) appraisal was performed by one reviewer. A revision-stage source and analysis-unit audit led to withdrawal of the planned inverse-variance meta-analyses and their ±0.5 mm equivalence claims; structured study-level synthesis was used instead.

O que encontraram

Eight studies addressed linear measurements; two additional reports were retained only as methodological context. Seven linear-measurement studies compared protocols within a device, and one compared different devices. All were experimental. In one five-skull study, mean absolute errors were 0.50, 0.46, and 0.51 mm at 40, 20, and 7 s, respectively. A cadaver study reported mean absolute errors of approximately 1.10-1.20 mm. Small mean between-protocol differences sometimes coexisted with impaired anatomical visibility. Repeated observations were not equivalent to independent specimens, and several required sampling variances could not be reconstructed.

Por que isso importa

Selected within-device protocol changes may preserve average measurements under controlled experimental conditions. The evidence does not establish statistical equivalence, interchangeability of protocol classes, or clinical safety near critical anatomy. Validation in living patients is needed before broad implementation.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Within-Device Exposure-Setting and Voxel-Size Changes in CBCT Alveolar Bone Measurement for Implant Planning: A Systematic Review

Ahmed Samir Elkattan, Mónica Piña-DAbreu, Pere Riutord-Sbert, Mónica Blázquez-Hinarejos, Jose López-López, Hassan Ahmed Assiri, Angel Arturo López González

Descritores MeSH

  • Alveolar Process
  • Cone-Beam Computed Tomography
  • Humans
  • Patient Care Planning
  • Dental Implants

Veja também

Estudos relacionados