Airway occlusions to measure inspiratory effort, respiratory drive, and lung mechanics during noninvasive ventilation
PneumologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
In intubated patients, occlusion maneuvers allow noninvasive assessment of inspiratory effort, respiratory drive, and lung mechanics.
To assess the feasibility of occlusion maneuvers during noninvasive ventilation (NIV).
In this multicenter study, 60 hypoxemic patients underwent 2 randomized 1-hour NIV sessions with oronasal and full-face masks after extubation. End-expiratory and end-inspiratory occlusions measured expiratory occlusion pressure (Pocc), 100-ms airway pressure drop (P0.1), and plateau pressure. Esophageal manometry, calibrated before extubation, provided reference values for inspiratory effort, assessed as esophageal pressure swing (ΔPes) and dynamic transpulmonary driving pressure (ΔPL,dyn = pressure support - ΔPes). Interface-specific conversion factors (K) translating Pocc into predicted ΔPes (K × Pocc) and predicted ΔPL,dyn (pressure support - predicted ΔPes) were derived through 100-interaction cross-validation (20-patient derivation set, 40-patient validation set).
O que encontraram
Pocc was measurable in all patients. Mean K was 0.71 with the oronasal mask and 0.80 with the full-face mask. Predicted ΔPes agreed with observed ΔPes (oronasal: bias -0.41 cm H2O, 95% limits of agreement -2.3 to 1.5; full-face: 0.09, -2.9 to 3.1), and predicted ΔPL,dyn agreed with observed ΔPL,dyn (oronasal bias: 0.03, -2.9 to 2.9; full-face: -0.04, -4.3 to 4.2). Predicted ΔPes identified observed ΔPes ≤ -10 cm H2O, with areas under the receiver operating characteristic curve of 0.98 (oronasal) and 0.97 (full-face). Ventilator-derived P0.1 did not precisely quantify respiratory drive, but values >2.7 cm H2O with the oronasal mask and >3 cm H2O with the full-face mask identified high drive with specificity >90%. Plateau pressure was unstable in 78% (oronasal) and 90% (full-face) of patients. More negative predicted ΔPes, higher predicted ΔPL,dyn, and lower predicted lung compliance (expiratory tidal volume/predicted ΔPL,dyn) were associated with subsequent reintubation.
Por que isso importa
During NIV, Pocc-derived parameters provide noninvasive estimates of inspiratory effort, lung stress, and mechanics, whereas ventilator P0.1 and plateau pressure are less reliable.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
Airway occlusions to measure inspiratory effort, respiratory drive, and lung mechanics during noninvasive ventilation
Francesco Murgolo, Domenico L Grieco, Rossana Soloperto, Michele Bertoni, Savino Spadaro, Nicola Bartolomeo, Tommaso Pettenuzzo, François Beloncle, Delphine Venkatapen, Alessandro Cardu et al.
Descritores MeSH
- Respiratory Mechanics
- Noninvasive Ventilation
- Feasibility Studies
- Female
- Humans
- Aged
- Manometry
- Masks
- Middle Aged
- Male
Veja também
Estudos relacionados
- Association of Noninvasive Oxygenation Strategies With All-Cause Mortality in Adults With Acute Hypoxemic Respiratory Failure: A Systematic Review and Meta-analysis
- Noninvasive Ventilation for Preoxygenation during Emergency Intubation
- A randomized controlled trial of the intraoperative use of noninvasive ventilation versus supplemental oxygen by face mask for procedural sedation in an electrophysiology laboratory
- Incidence of oxygen desaturation using a high-flow nasal cannula versus a facemask during flexible bronchoscopy in patients at risk of hypoxemia: a randomised controlled trial
- Desempenho preditivo dos parâmetros fisiológicos à beira do leito para falha da ventilação profilática não invasiva após extubação
- Physiological effects of noninvasive respiratory support strategies in adults with acute hypoxemic respiratory failure: a systematic review and network meta-analysis