ScienceMed®
Imagem de arquivo, ilustrativa: Medula óssea ao microscópio óptico: formação das células do sangue (hematopoese)

Accuracy of a point-of-care CoaguChek test versus standard laboratory coagulation monitoring in cardiac surgery involving cardiopulmonary bypass: randomized clinical trial

Hematologia
Imagem de arquivo, ilustrativa — não é do estudo. Medula óssea ao microscópio óptico: formação das células do sangue (hematopoese). Mikael Häggström · CC0 · Wikimedia Commons

Ensaio clínico randomizadoNível 2 · Nova evidênciaBrazilian journal of anesthesiology (Elsevier)22 nov 20250 citações

Por ScienceMed · · a partir do resumo dos autores

Salvar

Resumo original em inglês

O que aconteceu

Intraoperative coagulopathies are common in complex surgeries, and timely coagulation monitoring is crucial. We assessed the accuracy of the point-of-care CoaguChek XS test against standard laboratory measurements in patients undergoing cardiac surgery with Cardiopulmonary Bypass (CPB).

We conducted a single-center, diagnostic accuracy study to assess the coagulation profile of 50 participants before and after CPB. The index test was the CoaguChek XS device and the reference test was the standard laboratory assay. The primary outcome was the accuracy of the CoaguChek device in measuring the International Normalized Ratio (INR). We pre-specified a tolerance range of ± 0.5 INR units. Secondary outcomes included accuracy in measuring prothrombin time and prothrombin activity.

Plataforma Brasil CAAE 70266023.8.0000.5553.

(https://clinicaltrials.gov/study/NCT06037720) NCT06037720, 14/09/2023.

O que encontraram

We included 50 patients undergoing cardiac surgery with CPB between October 2023 and January 2024. The mean (standard deviation) age was 59.2 (12.3) years, and 32 participants (64%) were male. For INR values, Lin's coefficient was 0.72 (95% CI: 0.60‒0.82) pre-CPB and 0.66 (95% CI: 0.50‒0.77) post-CPB, both indicating good agreement. In the pre-CPB period, on average, the index test readings exceeded reference readings by 0.045 INR units (95% CI: 0.030‒0.059, p < 0.001), while in post-CPB period, index readings were, on average, 0.064 INR units lower (95% CI: -0.09 to -0.04, p < 0.001). Although statistically significant differences were observed, they fell within predefined tolerance range and were considered clinically irrelevant. Analyses of secondary outcomes were consistent with the primary outcome findings.

Por que isso importa

In patients undergoing cardiac surgery with cardiopulmonary bypass, CoaguChek XS provided results comparable to standard laboratory coagulation monitoring, both pre-and post-cardiopulmonary bypass.

Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.

O estudo original

Accuracy of a point-of-care CoaguChek test versus standard laboratory coagulation monitoring in cardiac surgery involving cardiopulmonary bypass: randomized clinical trial

Fabrício Tavares Mendonça, Sérgio Honorato de Matos, Larissa Goveia Moreira, Igor Louza Pereira, Lorenzo Leite Dino, Matheus Beserra Braga, Gustavo Henrique Dos Santos Dias

Descritores MeSH

  • Cardiac Surgical Procedures
  • Cardiopulmonary Bypass
  • Monitoring, Intraoperative
  • Point-of-Care Systems
  • Blood Coagulation Disorders
  • Middle Aged
  • Prothrombin Time
  • Aged
  • International Normalized Ratio
  • Blood Coagulation Tests