A controlled trial comparing dosimetry and radiation pneumonitis between tomotherapy and IMRT in patients with lung or esophageal cancer
OncologiaPor ScienceMed · · a partir do resumo dos autores
Resumo original em inglês
O que aconteceu
The expanding clinical use of helical tomotherapy (HT) has raised concerns regarding its potential to increase low-dose lung exposure and the risk of radiation pneumonitis (RP) in thoracic radiotherapy. While a few retrospective studies have compared dosimetric parameters and RP rates between HT and fixed-field intensity-modulated radiation therapy (IMRT), their findings remain inconsistent, necessitating a prospective randomized controlled trial for clarification.
To prospectively compare dosimetric parameters and the incidence of RP between HT and IMRT in patients with lung or esophageal cancer.
Patients eligible for thoracic radiotherapy were enrolled. Both HT and IMRT plans were designed and optimized for each patient, with a prescription equivalent dose in 2 Gy /fraction (EQD2) ≥50 Gy to the gross tumor volume (GTV). Plans were evaluated based on target dose coverage, dose-volume histograms, and other dosimetric indices. RP was diagnosed and graded according to the Common Terminology Criteria for Adverse Events (version 5.0). Risk factors for RP were identified using univariate analysis.
O que encontraram
Between February and September 2022, 110 consecutive patients with lung or esophageal cancer were enrolled and randomly assigned in a 1:1 ratio to either the HT group (n = 54) or the IMRT group (n = 56). Compared with IMRT, HT had a significant reduction in lung V20 (p = 0.002) and mean lung dose (p = 0.013). Furthermore, the HT group exhibited a superior conformity index for the planning gross tumor volume of the primary lesion (PGTVp) (p = 0.004) and a lower homogeneity index for all planning target volumes (PTVs) (p < 0.001). At a median follow-up of 14.0 months, the rate of grade≥2 RP for the entire cohort was 14.5%, with no significant differences between the HT and IMRT groups (p = 0.61).
Por que isso importa
Compared with fixed-field IMRT, HT provided superior dose distribution to the PTVs while maintaining a comparable incidence of RP in patients undergoing thoracic radiotherapy.
Resumo publicado sob licença CC BY. A tradução para o português ainda não chegou a este estudo.
O estudo original
A controlled trial comparing dosimetry and radiation pneumonitis between tomotherapy and IMRT in patients with lung or esophageal cancer
Anmei Zhang, Yang Zhang, Jingyun Yang, Lu Chen, Na Wu, Jindong Qian, Hongya Dai, Dingqiang Yang, Lirong Zhao, Liangzhi Zhong et al.
Descritores MeSH
- Lung Neoplasms
- Radiotherapy Planning, Computer-Assisted
- Radiation Pneumonitis
- Radiotherapy, Intensity-Modulated
- Esophageal Neoplasms
- Humans
- Male
- Middle Aged
- Prognosis
- Prospective Studies
Veja também
Estudos relacionados
- Mono iso-centric VMAT planning for SBRT of multiple liver metastasis- A case report
- Revisão sistemática dos critérios físicos e dosimétricos para o manejo dos DEICs em radioterapia: Perspectiva do físico médico
- A reoptimização completa é necessária na radioterapia adaptativa para câncer de cabeça e pescoço? Revisão sistemática dos resultados dosimétricos e clínicos
- A systematic review of the dosimetric consequences of the interplay effect